Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Electric Type |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Waterproof anti-electric shock protector is to generate a "zero-potential electric field" through its internal circuitry and chips, which blocks the conductive loop between the human body and the ground. This mechanism mimics the effect of a well-grounded metal enclosure in electrical leakage protection. Simultaneously, the device employs a collector (comprising a switching power supply, CPU chip, etc.) to capture stray currents and electrons from the conductors. By leveraging a counteracting magnetic field, these residual charges are redirected back into the electric field. As a result, only voltage (without current flow) exists in the water, effectively preventing electric shock.Suggested Specifications
Residential Use: 6A, 10A, 16A, 20A, 32A (e.g., lighting, sockets, air conditioners).
Industrial Use: 63A, 100A, 250A or higher (for motors, power distribution cabinets, etc.).
Type
|
CB-125
|
CB-250
|
CB-400
|
CB-630
|
|
Rated Current Of Frame
|
125
|
250
|
400
|
630
|
|
Pole
|
3P+N 4P
|
3P+N 4P
|
3P+N 4P
|
3P+N 4P
|
|
Rated Working Voltage Ue(v)
|
AC 400 50Hz
|
||||
Rated Insulation Voltage Ui(v)
|
8000
|
||||
Flashover Distance
|
≥50
|
≥50
|
≥100
|
≥100
|
|
Rated Ultimate Short Circuit
|
50
|
50
|
65
|
65
|
|
Breaking Capacity Lcu(ka)
|
|||||
Rated Serviec Short Circuit
|
35
|
35
|
42
|
50
|
|
Breaking Capacity Lcs(ka)
|
|||||
Rated Residual Short Circuit
|
12.5
|
12.5
|
20
|
20
|
|
Breaking Capacity (ka)
|
|||||
Rated Short time
|
1.5kA/1s
|
3kA/0.5s
|
5kA/0.5s
|
8kA/0.5s
|
|
Withstand Current Icw(ka)
|
|||||
Residual Current Action Character Istics
|
AC Type
|
||||
Rated Residual Operating Current
|
100mA,300mA,500mA,1000mA(Adjustable grading)
|
||||
Ratedual Action Time Character Istics
|
Time-delay Type(0.5s)/non Time-delay Type(0.3)
|
||||
time-delay type limit non-acting time(s)
|
t≥0.06 :2l n
|
||||
Breaking Time(s)
|
l n≤0.5; 21 n≤0.2; 5lAn≤0.15
|
||||
Automatic Realosing Time
|
20-60
|
||||
Operting
|
No
|
1500
|
1000
|
1000
|
2000
|
performance
|
OFF
|
8500
|
7000
|
4000
|
8000
|
(times)
|
Total times
|
10000
|
8000
|
5000
|
10000
|
Overloa short circuit characteristic
|
Three-sect Protection Electronic Adjustable
|
||||
Detailed"descrIption Of Protection Features"
|
|||||
over-voltage protection value(V)
|
Value(250~300)±5%
|
||||
Under voltage protection value(V)
|
Value (150~200)±5%
|
||||
joint control delay time(ms)
|
≤40ms
|
||||
Comunication delay time(ms)
|
≤200ms
|
Application